| Location |
IMOS Capricorn Channel Mooring. Deployed 29/8/2010 |
| GPS |
22° 24.49' S, 151° 59.595' E |
| Deployment Type |
Mooring |
| Instrument |
WQM_138 |
| Description |
WETLABS, WQM, serial no. 138 |
| Capability |
OCEAN
FL 0-30
NTU 0-10
PRESS 0-100m
Housing 200m
1GB Memory
|
| Sample Type |
CTD, DO, FLNTU |
| Sampling |
Firmware V1.23
Autonomous
1min/15min Samples
BLIS ON
Purge When Insitu On
BLIS Interval: 1 Hour
BLIS Volume: 28 µl
DO units mg/l
Fixed DO=60s
Conductivity added to output
MEM:223 Days 1022783 kb
15.99V
Battery Canister BPA50-IM #114
Setup File 1381008.nsf
|
| Sample Depth |
12 (m from bottom) |
| Time : Switch On |
29/08/2010 at 09:58:20 UTC/GMT |
| Time : First Wet |
29/08/2010 at 23:05:08 UTC/GMT |
| Time : First Good |
29/08/2010 at 23:20:57 UTC/GMT |
| Time : Last Good |
04/03/2011 at 20:35:00 UTC/GMT |
| Time : On Deck |
04/03/2011 at 20:51:00 UTC/GMT |
| Time : Switch Off |
05/03/2011 at 01:37:00 UTC/GMT |
| Comment |
8 files: WQM0138_020 - WQM0138_027
Largest one is WQM0138_020. Battery voltage on recovery 13.22V. Locking sleeve on comms cable hard to remove. Pin 2 on Battery
cable was corroded and swollen. Cable and bulkhead connector need replacing on BPA501M#114. No water in housing. 6 pin bulkhead
leakiing onto power board.
|
| Filename |
DATA/TRIP005172/WQM0138_020.dat |